The things about glass
nobody explains.
A technical data sheet with every quote, a glass suggestion based on your needs, samples on your desk and one technical contact for all your projects.
Solar control, acoustics, safety, regulations and selection guides.
Why ground edges on insulating glass?
Thermal stress breakage always starts at the edge. That is why we grind every pane that goes into a unit.
ReadUg versus g-value: why standard triple glazing does not solve summer
Why Ug alone is not enough for summer and what does the job, with figures for our triple-glazed units.
ReadWhat the numbers on glass mean
Ug, g, LT, Rw, Ψ, EN 356 and the other values you see on a quote or a technical data sheet, each in brief.
ReadInsulating glass units: installation, sealants and storage
Why acetoxy silicones must not touch the unit, rebate drainage, storage and transport.
ReadHow to reach Rw 42 dB on a window next to a road
Asymmetric panes, acoustic PVB interlayer, cavity width. What actually works.
ReadToughened glass: roller waves, spots and other things that are not defects
Waves in reflections, rainbow spots under polarised light, bow. What is normal, what EN 12150-1 allows and how to choose glass so that it shows least.
ReadToughened or laminated? When to choose which?
Impact, falls, break-ins, fire. A short guide by application, with EN 12600 classes.
ReadEPBD 2024: what the new directive asks of the building envelope
Limit values, the energy performance certificate and the role of the g-value in the calculation.
ReadA technical data sheet
with every quote.
For every insulating, laminated or toughened glass configuration, we send a technical data sheet with Ug, g, LT, Ra and Rw values to EN 673 / EN 410, from the calculator. On request, a BoQ item description too, ready to paste in.
- Technical data sheet with the quote, no waiting
- Ug, g, LT and Rw for fifteen make-ups, right here on the site
- BoQ item description on request
- BIM file for the glass on request, for your building model
- Installation details for balustrades, partitions and façades, project by project
Into your BoQ,
in one click.
Our most common make-ups, each also with solar control. Click a name for the full text; “Copy” puts it on your clipboard, ready for the bill of quantities.
IG 4+16+Low-E 4 [24 mm]
Double-glazed insulating glass unit 4 + 16 + 4 mm, overall thickness 24 mm. Make-up, outside to inside: 4 mm float glass; 16 mm cavity, argon-filled (90%); 4 mm float glass with low-E coating on surface 3. Warm edge spacer. Ug = 1.1 W/m²K (EN 673), g = 63.9% (EN 410), LT = 81.9%, Rv (external) = 12.4%, Rw (C; Ctr) = 30 (−1; −4) dB (calculated).
IG Sun4+16+4 [24 mm]
Double-glazed insulating glass unit 4 + 16 + 4 mm, overall thickness 24 mm. Make-up, outside to inside: 4 mm float glass with solar control coating on surface 2; 16 mm cavity, argon-filled (90%); 4 mm float glass. Warm edge spacer. Ug = 1.0 W/m²K (EN 673), g = 34.9% (EN 410), LT = 70.5%, Rv (external) = 13.6%, Rw (C; Ctr) = 30 (−1; −4) dB (calculated).
IG Sat 4+16+Low-E 4 [24 mm]
Double-glazed insulating glass unit 4 + 16 + 4 mm, overall thickness 24 mm. Make-up, outside to inside: 4 mm satin glass (acid-etched); 16 mm cavity, argon-filled (90%); 4 mm float glass with low-E coating on surface 3. Warm edge spacer. Ug = 1.1 W/m²K (EN 673), g = 62.9% (EN 410), LT = 80.5%, Rv (external) = 12.2%, Rw (C; Ctr) = 30 (−1; −4) dB (calculated).
IG Sun4+16+Sat 4 [24 mm]
Double-glazed insulating glass unit 4 + 16 + 4 mm, overall thickness 24 mm. Make-up, outside to inside: 4 mm float glass with solar control coating on surface 2; 16 mm cavity, argon-filled (90%); 4 mm satin glass (acid-etched). Warm edge spacer. Ug = 1.0 W/m²K (EN 673), g = 34.9% (EN 410), LT = 69.3%, Rv (external) = 13.6%, Rw (C; Ctr) = 30 (−1; −4) dB (calculated).
IG 4+12+Low-E 4 [20 mm]
Double-glazed insulating glass unit 4 + 12 + 4 mm, overall thickness 20 mm. Make-up, outside to inside: 4 mm float glass; 12 mm cavity, argon-filled (90%); 4 mm float glass with low-E coating on surface 3. Warm edge spacer. Ug = 1.3 W/m²K (EN 673), g = 63.9% (EN 410), LT = 81.9%, Rv (external) = 12.4%, Rw (C; Ctr) = 30 (−1; −3) dB (calculated).
IG Sun4+12+4 [20 mm]
Double-glazed insulating glass unit 4 + 12 + 4 mm, overall thickness 20 mm. Make-up, outside to inside: 4 mm float glass with solar control coating on surface 2; 12 mm cavity, argon-filled (90%); 4 mm float glass. Warm edge spacer. Ug = 1.2 W/m²K (EN 673), g = 35.0% (EN 410), LT = 70.5%, Rv (external) = 13.6%, Rw (C; Ctr) = 30 (−1; −3) dB (calculated).
IG Low-E 4+16+4+16+Low-E 4 [44 mm]
Triple-glazed insulating glass unit 4 + 16 + 4 + 16 + 4 mm, overall thickness 44 mm. Make-up, outside to inside: 4 mm float glass with low-E coating on surface 2; 16 mm cavity, argon-filled (90%); 4 mm float glass; 16 mm cavity, argon-filled (90%); 4 mm float glass with low-E coating on surface 5. Warm edge spacer. Ug = 0.6 W/m²K (EN 673), g = 52.7% (EN 410), LT = 74.1%, Rv (external) = 15.9%, Rw (C; Ctr) = 32 (−1; −5) dB (calculated).
IG Sun4+16+4+16+Low-E 4 [44 mm]
Triple-glazed insulating glass unit 4 + 16 + 4 + 16 + 4 mm, overall thickness 44 mm. Make-up, outside to inside: 4 mm float glass with solar control coating on surface 2; 16 mm cavity, argon-filled (90%); 4 mm float glass; 16 mm cavity, argon-filled (90%); 4 mm float glass with low-E coating on surface 5. Warm edge spacer. Ug = 0.5 W/m²K (EN 673), g = 32.4% (EN 410), LT = 63.9%, Rv (external) = 16.1%, Rw (C; Ctr) = 32 (−1; −5) dB (calculated).
IG Low-E 4+12+4+12+Low-E 4 [36 mm]
Triple-glazed insulating glass unit 4 + 12 + 4 + 12 + 4 mm, overall thickness 36 mm. Make-up, outside to inside: 4 mm float glass with low-E coating on surface 2; 12 mm cavity, argon-filled (90%); 4 mm float glass; 12 mm cavity, argon-filled (90%); 4 mm float glass with low-E coating on surface 5. Warm edge spacer. Ug = 0.7 W/m²K (EN 673), g = 52.7% (EN 410), LT = 74.1%, Rv (external) = 15.9%, Rw (C; Ctr) = 31 (−1; −5) dB (calculated).
IG Sun4+12+4+12+Low-E 4 [36 mm]
Triple-glazed insulating glass unit 4 + 12 + 4 + 12 + 4 mm, overall thickness 36 mm. Make-up, outside to inside: 4 mm float glass with solar control coating on surface 2; 12 mm cavity, argon-filled (90%); 4 mm float glass; 12 mm cavity, argon-filled (90%); 4 mm float glass with low-E coating on surface 5. Warm edge spacer. Ug = 0.7 W/m²K (EN 673), g = 32.5% (EN 410), LT = 63.9%, Rv (external) = 16.1%, Rw (C; Ctr) = 31 (−1; −5) dB (calculated).
IG 4+16+4+16+Low-E 4 [44 mm]
Triple-glazed insulating glass unit 4 + 16 + 4 + 16 + 4 mm, overall thickness 44 mm. Make-up, outside to inside: 4 mm float glass; 16 mm cavity, argon-filled (90%); 4 mm float glass; 16 mm cavity, argon-filled (90%); 4 mm float glass with low-E coating on surface 5. Warm edge spacer. Ug = 0.9 W/m²K (EN 673), g = 58.6% (EN 410), LT = 75.0%, Rv (external) = 18.7%, Rw (C; Ctr) = 32 (−1; −5) dB (calculated).
IG Sun4+16+4+16+4 [44 mm]
Triple-glazed insulating glass unit 4 + 16 + 4 + 16 + 4 mm, overall thickness 44 mm. Make-up, outside to inside: 4 mm float glass with solar control coating on surface 2; 16 mm cavity, argon-filled (90%); 4 mm float glass; 16 mm cavity, argon-filled (90%); 4 mm float glass. Warm edge spacer. Ug = 0.8 W/m²K (EN 673), g = 32.5% (EN 410), LT = 64.7%, Rv (external) = 17.9%, Rw (C; Ctr) = 32 (−1; −5) dB (calculated).
IG SNX 50 8+16+Lami 4.4.2 [32.76 mm]
Double-glazed insulating glass unit 8 + 16 + 4.4.2 mm, overall thickness 32.76 mm. Make-up, outside to inside: 8 mm toughened glass with solar control coating on surface 2; 16 mm cavity, argon-filled (90%); 4.4.2 laminated glass (two 4 mm float panes, 2 × 0.38 mm PVB interlayers). Warm edge spacer. Ug = 1.0 W/m²K (EN 673), g = 24.0% (EN 410), LT = 49.4%, Rv (external) = 10.2%, Rw (C; Ctr) = 38 (−2; −5) dB (calculated).
IG Lami SN70S 6.6.2+16+10 [38.76 mm]
Double-glazed insulating glass unit 6.6.2 + 16 + 10 mm, overall thickness 38.76 mm. Make-up, outside to inside: 6.6.2 laminated glass (two 6 mm float panes, 2 × 0.38 mm PVB interlayers) with solar control coating on surface 2 (facing the cavity); 16 mm cavity, argon-filled (90%); 10 mm float glass. Warm edge spacer. Ug = 1.0 W/m²K (EN 673), g = 36.2% (EN 410), LT = 68.1%, Rv (external) = 10.9%, Rw (C; Ctr) = 43 (−2; −5) dB (calculated).
IG Sunguard SG 8+16+Low-E 8 [32 mm]
Double-glazed insulating glass unit 8 + 16 + 8 mm, overall thickness 32 mm. Make-up, outside to inside: 8 mm toughened glass with grey reflective solar control coating on surface 2; 16 mm cavity, argon-filled (90%); 8 mm float glass with low-E coating on surface 3. Warm edge spacer. Ug = 1.1 W/m²K (EN 673), g = 25.4% (EN 410), LT = 29.1%, Rv (external) = 23.9%, Rw (C; Ctr) = 35 (−1; −4) dB (calculated).
Values from Guardian’s performance calculator (EN 673, EN 410); Rw is calculated, not measured. The text is neutral, with no manufacturer or trade names, as public procurement requires. For any other make-up, send us an enquiry and we will include the item description with the quote.
Run the numbers before the quote.
Build your own insulating glass unit
A few questions: which way the windows face, large or small, and what matters to you. The tool suggests the glass.
Answer the questionsOrder a sample
Tell us which samples you would like and your office address: solar control, acoustic laminated glass, balustrade glass, satin and decorative glass. We send samples by post.
Order by emailOne person
for all your projects.
For specifiers, architects and contractors: one person who knows your project. They check the glass make-up, calculate Ug and g for each façade and suggest the right laminated glass for a balustrade. Half an hour on the phone often saves a week of emails.

Technical support
For specifiers and contractors
+385 31 852 000
info (at) eurostaklo.hr
Send us your opening schedule
or a project brief.
We reply with a quote and a technical data sheet, and on request a specification clause for your bill of quantities.